Following is the limitation of the SAS provider:
SAS is a read-only provider and hence does not allow users to modify, create, or delete
instances.
When SAS provider B.11.31.1106 or later is installed on legacy Integrity systems,
dm_sas_adapter is never launched regardless of the diag mode.
HPUXSASNativeIndicationProviderModule always monitors natively the hardware and generates
WBEM events. The reverse wrapper, sas_Wbemwrapper, may be launched depending on
the connected hardware. This reverse wrapper converts the WBEM event to the corresponding
EMS event.
The introduction of this native support adds to support the following EMS resource path:
/adapters/events/sas_wrapper_wbem
On the other hand, as the process for dm_sas_adapter is never launched, the corresponding
EMS resource path is not monitored:
/adapters/events/sas_adapter
Related documentation
Table 8 lists the available documentation for the WBEM providers:
Table 8 WBEM provider related documents
LocationDescription
http://www.dmtf.org/standards/cimCIM Tutorial
http://software.hp.com
and
Information about HP WBEM Services
http://www.hp.com
http://www.openpegasus.org/uploads/40/3452/WBEMIndications.pdfOverview of the indication schema
Datasheets of all the providers are installed along with the product at the following
location on the system:/opt/<provider-name>/doc
Provider Datasheets
The datasheets are also available at the following location:
www.hp.com/go/hpux-networking-docs and select HP-UX 11i WBEM Software
collection.
Localized version of the software
The product is supported only in English locale (LANG=C). Behavior of the product is unpredictable
when LANG value is set to any other language code other than C. Documentation support for this
product is also available only in English locale.
Related documentation 9