HP Caliper User Guide Release 5.5 (5900-2351, August 2012)

NOTE: The target process being measured does not terminate when HP Caliper detaches from
it. The process keeps running (in the background if it was launched by HP Caliper).
How to Display Reference Information About CPU Counters or HP Caliper
Report Types
You can use the caliper info command to display reference information about the CPU counters
or HP Caliper report descriptions. You can specify a partial name of a CPU counter or a
measurement name to get information on all items that match.
By default, it is assumed that you want to see counter information, not report information.
Figure 23 (page 101) shows some example output of the caliper info command. In this case,
the following command is specified:
$ caliper info cycle
Figure 23 Example Output of the caliper info Command
$ caliper info cycle
================================================================================
HP Caliper 4.3.0 CPU Counter Information
================================================================================
Name: BUS_DATA_CYCLE
Abbreviation: BDC or BUS_D
Title: Valid Data Cycle on the Bus
Definition: Counts the number of BUS Clocks which had a valid data cycle on
the bus.
Name: BUS_SNOOP_STALL_CYCLES.ANY
Abbreviation: BSSCA or BUS_SNOOP_STALL_CYCLES.A
Title: Bus Snoop Stall Cycles (from any agent)
Definition: Counts the number of bus clocks FSB is stalled for snoop (this is
twice the number of bus clocks HIT and HITM are asserted at the
same time).
Umask Descr: Counts snoops from the CPU or non-CPU (all snoops)
Name: BUS_SNOOP_STALL_CYCLES.SELF
Abbreviation: BSSCS or BUS_SNOOP_STALL_CYCLES.S
Title: Bus Snoop Stall Cycles (from any agent)
Definition: Counts the number of bus clocks FSB is stalled for snoop (this is
twice the number of bus clocks HIT and HITM are asserted at the
same time).
Umask Descr: Only counts snoops from the local CPU
Name: CPU_CYCLES
Abbreviation: CC or CPU_CY
Title: CPU Cycles
Definition: Counts the number of clock cycles.
================================================================================
If you specify multiple CPU events or reports, then HP Caliper displays information on all matches.
Options for the caliper info Command
The options for the caliper info are not case-sensitive and can be abbreviated.
-c or --cpu-counter
-c counter_name|keyword|all
Specifies what kind of information about the CPU counters should be output. You can specify a
partial name.
Use all for information on all CPU counters.
How to Display Reference Information About CPU Counters or HP Caliper Report Types 101