HP DCE/9000 Application Development Tools for HP-UX 11i Release Note

10
HP DCE/9000 Version 1.8 Application Development Tools for HP-UX 11i Release Note
Known Problems and Workarounds
Known Problems and Workarounds
This section describes known problems and workarounds in the HP DCE version 1.8
Application Development Tools for HP-UX 11i.
SR - No 8606-165933
Secd does not log trace for sec component via dcecp command
SR - No 8606-169328
cdsd returns wrong ACL to dcecp
DCE-Core Tools
As of DCE 1.6, the DCE_SVC_DEBUG macro was changed to acquire a SVC mutex lock (in
prior releases this was done in the serviceability library). Because of this, DCE applications
based on DCE 1.5 and earlier releases that make use of this macro will be binary incompatible
with DCE 1.6 applications and so must be recompiled under DCE 1.6 on HP-UX 10.30.
DCE-C-Tools
There are no problems in HP DCE-C-Tools discovered at HP DCE 1.5, 1.7, or 1.8.