29. ISCSI_LOG_SSN_RESOLV_FAIL LVL_ERR
"Unable to resolve the Target Hostname (%s)."
The specified Hostname is not a Qualified Domain Name. This will cause the target
port
hostname resolution to fail. Check if the hostname specified for the target port
is a Qualified
Domain Name. If the problem persists, please contact your network administrator
for further assistance.
30. ISCSI_LOG_SSN_ROUTE_FAIL LVL_ERR
"No route found for IP address (%s)."
The initiator is not able to reach the specified target address. The specified IP
address for the target is changed resulting in no route to the target. Check if
the connection between initiator and target is physically secure and established.
Check if the target has the same IP address as displayed in the log message. If
the problem persists, please contact your network administrator for further
assistance.
31. ISCSI_LOG_INCOR_KEY LVL_ERR
"Invalid text key (%s) received from the target in \n"
"SendTargets response."
An invalid text key was received from the target in response to a SendTargets
request. The login failed as a result of this protocol violation. This
information should be presented to the target vendor for resolution.
32. ISCSI_LOG_INCOR_TGT_ADDR LVL_ERR
"Invalid key value (%s) received from the target for \n"
"TargetAddress key."
The specified invalid key value was received from the target for
theTargetAddress. The login failed as a result of this protocol violation. The
information should be presented to the target vendor for resolution.
33. ISCSI_LOG_LOGIN_NO_CHAP_SECRET LVL_WARN
"The initiator CHAP secret is not configured."
CHAP authentication failed as the CHAP initiator secret is not configured. Use
the iscsiutil command to configure the CHAP initiator secret.
34. ISCSI_LOG_BAD_ISCSI_NAME LVL_ERR
Initiator received an iSCSI name from a target that was in an invalid format. The
target cannot be recognized by the iSCSI initiator as a result.
35. ISCSI_LOG_INCOR_KEY_REDI LVL_ERR
"Invalid text key (%s) received from the target in"
"a login redirection response."
A key that wasnt a TargetAddress key was received
while processing a login redirection request.
36. ISCSI_LOG_TEMP_REDIRECT_REQUESTED LVL_INFO
"Login response with status code (0x%x) to"
"TargetAddress %s indicated a"
"temporary redirection request to %s."
During login,an iSCSI target device requested
the initiator to perform a temporary login redirection
to a new TargetAddress.
37. ISCSI_LOG_PERM_REDIRECT_REQUESTED LVL_INFO
"Login response with status code (0x%x) to"
"TargetAddress %s indicated a"
"permanent redirection request to %s."
During login,an iSCSI target device requested the
initiator to perform a permanent login redirection
to a new TargetAddress.
38. ISCSI_LOG_REDIRECT_OCCURRED LVL_INFO
"Login to TargetAddress %s was redirected"
"successfully to %s."