Administrator's and User's Guide for SFM HP-UX 11i v3 March 2012

Table 1 Instance providers (continued)
DescriptionInstance provider
For more information on the DAS provider, see the HP-UX WBEM Direct
Attached Storage (DAS) provider Data Sheet and Release Notes at: http://
www.hp.com/go/hpux-wbem-docs
Retrieves information about the management processor on the system.Management Processor
The Enclosure instance provider retrieves the following types of information:Enclosure
Onboard Administrator (OA) description
OA IP address
OA MAC address
URL to launch the OA
NOTE: The Enclosure instance provider is available on all integrity Blade
systems except for BL60p and HP Integrity Superdome 2.
The Temperature Sensor provider retrieves the following types of information:
Describes properties such as sensor number, current temperature reading,
and temperature sensor status.
Temperature Sensor
Sensor number
Current temperature reading
Temperature sensor status
Processor temperature
Memory board temperature
On HP 9000 and HP Integrity ® systems running a supported version of
HP-UX, the Temperature Sensor provider retrieves information related to the
ambient temperature in the system. On HP 9000 and HP Integrity ® system
not supporting the system and numeric sensor, the Temperature Sensor
instance provider doesn’t retrieve any information.
Enables event analysis tools such as Web-Based Enterprise Services (WEBES)
to access details of indications generated by the SFMIndicationProvider
Record Log
that are available in the SFM database, for event analysis. The provider
also supports MCA logs. Event analysis tools can access MCA log details
for event analysis.
For more information, see Recordlog and MCA indication provider at:
http://bizsupport1.austin.hp.com/bc/docs/support/SupportManual/
c02578184/c02578184.pdf
Retrieves properties such as the serial number, product ID, and virtual
Universally Unique ID (UUID). It provides the following details related to the
physical system:
ComputerSystem Chassis provider
SerialNumber
ProductId
Model
The ComputerSystem Chassis provider provides the following details related
to the logical server:
VirtualSerialNumber
VirtualUUID
These values are retained when an OS instance is moved to another server.
The Consolidated Status provider provides the overall health status of various
subsystems of the managed node. The overall health status is consolidated
from the health status of individual status providers registered with WBEM.
Consolidated Status provider
The SFM providers that contribute to the overall health status are:
Components of SFM 11