STM Release Notes for HP-UX 11i v1 December 2009 Release

this port, the diagmond process exits.
Workaround:
* set the parameter of LOCAL_ONLY_ENABLE in
the /var/stm/config/sys/diagmond.cfg file.
// Uncomment " LOCAL_ONLY_ENABLE 1 "
# Indicates whether remote systems are allowed to connect to the
# unit under test. If this flag is set to 1, only connections from
# UIs running on the unit under test will be accepted. All others
# will be ignored.
LOCAL_ONLY_ENABLE 1
Restart diagnostics by entering the following command:
# /sbin/init.d/diagnostic stop;sleep 10;/sbin/init.d/diagnostic start
Documentation
For the latest and most complete information on STM refer to the Diagnostics section of Hewlett-Packard's online
documentation Web site at:
http://www.hp.com/go/hpux-diagnostics-docs
This site provides manuals, tutorials, FAQs, and other reference material.
For the most current information on HP-UX 11i v1 diagnostics, see the following Web pages at the Diagnostics site:
EMS Release Notes for HP-UX 11i v1 December 2009 Release
STM Release Notes for HP-UX 11i v1 December 2009 Release
DIAGNOSTICS.readme
Online Help
Online help for STM is available at the following Web site.
http://www.hp.com/go/hpux-diag-stm-onlinehelp-doc
It is available on the local disk at:
xstm main help:
file:/usr/sbin/stm/catalog/C/HP-UX_B.11.11/ui/stmx.htm
mstm main help:
file:/usr/sbin/stm/catalog/C/HP-UX_B.11.11/ui/stmm.htm
cstm main help:
file:/usr/sbin/stm/catalog/C/HP-UX_B.11.11/ui/stmc.htm
SD Product Structure
The product number for STM is B6191AAE.