HP Process Resource Manager User's Guide

PRM error messages
prmlist error messages
Appendix G 279
822
Message No members found for netgroup %s for this
machine and domain.
Cause An empty or nonexistent netgroup was specified in a
user record.
Action Check the spelling in the PRM configuration file
against the spelling in the /etc/netgroup file and
correct if necessary. Alternatively, if the configuration
is used on multiple systems and the netgroup name
is valid on one of the other systems, do nothing.
823
Message Could not find compartment %s.
Cause Name given is not a compartment.
Action Check the spelling.
824
Message Could not find Unix group %s.
Cause Name given is not a Unix group.
Action Check the spelling.
831
Message Device record for %s not found.
Cause Name given is not a logical volume group.
Action Check the spelling, then use bdf to check whether
the device is mounted.
846
Message Could not find configuration file name.
Cause Could not find the name of the original configuration
file in the first two lines in the PRM internal working
file.
Action Reset PRM with prmconfig -r then load a
configuration and enable PRM.