HP-UX SNAplus2 R7 Administration Guide
Managing SNAplus2 Client/Server Systems
Managing Win32 clients
Name of the backup error log file. When the error log file reaches the size specified in error_file_wrap_size,
SNAplus2 copies its contents to the backup file (overwriting any existing file), then clears the error log file.
This parameter is optional. If it is not specified, the default is
bak.err.
To log error and audit messages to a single file, specify the same file name for both this parameter and the
backup_audit_file parameter.
error_file_wrap_size
The Registry data type of this value is REG_DWORD.
The maximum size of the log file specified by error_file. When a message written to the file causes the file
size to exceed this limit, SNAplus2 copies the current contents of the log file to the backup log file, then clears
the log file. This means that the maximum amount of disk space taken up by error log files is approximately
twice the value of the error_file_wrap_size parameter.
This parameter is optional. If it is not specified, the default is 1000000 (bytes). If you are logging error
and audit messages to the same file, this parameter must be set to the same value as the audit_file_wrap_size
parameter.
audit_file
The Registry data type of this value is REG_SZ.
Name of the file to which audit messages are written. This parameter is optional. If it is not specified, the
default is sna.aud.
To log error and audit messages to a single file, specify the same file name for both this parameter and the
error_file parameter.
backup_audit_file
The Registry data type of this value is REG_SZ.
Name of the backup audit log file. When the audit log file reaches the size specified in audit_file_wrap_size,
SNAplus2 copies its contents to the backup file (overwriting any existing file), then clears the audit log file.
This parameter is optional. If it is not specified, the default is bak.aud.
To log error and audit messages to a single file, specify the same file name for both this parameter and the
backup_error_file parameter.
audit_file_wrap_size
The Registry data type of this value is REG_DWORD.
The maximum size of the log file specified by audit_file. When a message written to the file causes the file
size to exceed this limit, SNAplus2 copies the current contents of the log file to the backup log file and clears
the log file. This means that the maximum amount of disk space taken up by audit log files is approximately
twice the value of the audit_file_wrap_size parameter.
This parameter is optional. If it is not specified, the default is 1000000 (bytes). If you are logging error
and audit messages to the same file, this parameter must be set to the same value as the error_file_wrap_size
parameter.
succinct_errors
The Registry data type of this value is REG_SZ.
Specifies whether to use succinct logging or verbose logging in the error log file. This setting applies to both
exception logs and problem logs. You can specify either of the following values:
YES
Use succinct logging: each message in the log file contains a summary of the message header
information (such as the message number and log type) and the message text string and parameters. To
obtain more details of the cause of the log and any action required, you can use the snaphelp utility
on a computer running HP-UX.
152