HP-UX SNAplus2 R7 Administration Guide
Managing SNAplus2 Client/Server Systems
Managing Win16 Clients
The maximum size of the trace file. If two file names are specified, tracing switches between the two files
when the current file reaches this size. If only one file name is specified, this parameter is ignored; the file
size is not limited.
This parameter is optional. If it is not specified, the default is
100000 (bytes).
admin_msg
To trace internal messages relating to client/server topology, set this parameter to YES; otherwise, set it to
NO.
This parameter is optional. If it is not specified, the default is NO.
datagram
To trace datagram messages, set this parameter to YES; otherwise, set it to NO.
This parameter is optional. If it is not specified, the default is NO.
data
To trace data messages, set this parameter to YES; otherwise, set it to NO.
This parameter is optional. If it is not specified, the default is NO.
send
To trace all data messages sent from the client to the server, set this parameter to YES; otherwise, set it to
NO.
This parameter is optional. If it is not specified, the default is NO.
receive
To trace all data messages received by the client from the server, set this parameter to YES; otherwise, set it
to NO.
This parameter is optional. If it is not specified, the default is NO.
[Appl_Name]
The [Appl_Name] section of the file specifies options for a CPI-C application. To set these options for one or
more applications, include a section in this format for each application, and replace the Appl_Name variable with
the application program’s executable name (not including the .exe file name extension).
For more information about CPI-C, refer to HP-UX SNAplus2 CPI-C Programmer’s Guide.
The options are specified as follows:
APPCLLU
The name of the local LU that this application uses.
This parameter is optional. If it is not specified, the application attempts to use the default LU (the LU
associated with a local node’s control point).
APPCTPN
The TP name of the application. This name is used in log and trace files to identify the application. For an
invoked application (one that issues Accept_Conversation), it is also used to match the TP name on an incoming
Allocate request with the correct application; the invoked application can also use the Specify_Local_TP_Name
call to specify additional names to be matched with incoming Allocate requests.
This parameter is optional. If it is not specified, the default is CPIC_DEFAULT_TPNAME.
[CSV_data]
The [CSV_data] section of the file specifies options for applications that use the CSV interface. It applies only
to applications that use the CONVERT verb to perform character conversion with a user-defined conversion table
(Table G). For more information about the CONVERT verb, refer to HP-UX SNAplus2 CSV Programmer’s Guide.
168