HP-UX SNAplus2 RJE User's Guide

SNAplus2 RJE Workstation Configuration
RJE Style File Records
Chapter 6144
To specify that both text records and transparent data
records are to be padded, specify the two constants
combined using a + character:
PAD_TEXT + PAD_TRANSP or
PAD_TEXT + PAD_TRANSP_SPACE
ff_passthrough
Specifies whether the workstation should pass through
Form (FF) characters received from the host in printer
output, or convert them to line-feed characters. This
option is ignored for punch output.
Allowed values:
YES
Pass through FF characters without
conversion.
NO
Convert FF characters to the
appropriate number of line-feed
characters to reach the end of the
page (as defined by the forms control
buffer used by the printer device).
Select the option that generates the output format
expected by the printer devices or output programs you
are using.
printer_nl
Specifies the maximum line length in characters for
printer output. The workstation will insert a new-line
character each time the output linereaches this length.
The valid range is 132 - 255. This option is ignored for
punch output.
console_log_size
Specifies the maximum size in bytes of each of the two
files used to hold console log data for this workstation,
in the range 10,000 - 1,000,000,000. The first file can
grow to the size specified here. Information is then
written to the second file. When the second file reaches