HP-UX SNAplus2 RJE User's Guide

SNAplus2 RJE Components and Operation
Processing Output Data
Chapter 3 63
Routing by usr Card
If you include usr card(s) in your files, rjeusr or rjeusrpad writes to the
file or directory you have specified in the
place
field. If rjeusr or
rjeusrpad cannot write to
place
, it logs an error message and notifies
you of the error by mail (see “Receiving Error Notification” in this
chapter).
In this case, rjeusr or rjeusrpad routes output to the base directory
and assigns a unique system generated name as described in this
chapter under “Routing Received Files Without a usr Card”.
Receiving Error Notification
Regardless of the value you have set for the notify field on the usr card, if
there is an error in the routing process, rjeusr or rjeusrpad will notify
you through mail of the error. Here is an example of the notification you
receive.
Example
The RJE workstation RJE1 has attempted to route output sent to
PRT1. An error has been detected: SNA9555
SNAplus2 RJE:9555: RJE1 PRT1 rjeusr/rjeusrpad - received
non-zero exit status after executing /users/user1/test. Output
will remain in /var/opt/sna/rje/RJE1/output/PRT1.
In this example, rjeusr or rjeusrpad routed the data to the base di
rectory, /var/opt/sna/rje/RJE1/output and kept the data in the file
with the system generated name PRT1.