Administrator's and User's Guide for SFM HP-UX 11i v1 April 2006

Troubleshooting SFM
Troubleshooting Indication Providers
Chapter 5 117
</KEYBINDING>
<KEYBINDING NAME="SystemName">
<KEYVALUE VALUETYPE="string">
hpdst348
</KEYVALUE>
</KEYBINDING>
</INSTANCENAME>
</VALUE.REFERENCE>
</KEYBINDING>
</INSTANCENAME>
Cause 5
The indication providers are not loaded properly.
Solution
To check whether the EMS Wrapper Provider is loaded properly,
complete the following steps:
Step 1. Open the /opt/sfm/conf/FMLoggerConfig.xml file.
Step 2. Using an editor, change the severity of logs from WARNING to
INFORMATIONAL.
Step 3. Enter the /opt/sfm/bin/fmdcontrol command with the
/opt/sfm/conf/FMLoggerConfig.xml option:
# /opt/sfm/bin/fmdcontrol /opt/sfm/conf/FMLoggerConfig.xml
Step 4. Enter the following command to generate a sample indication:
# /etc/opt/resmon/lbin/send_test_event <monitor_name>
For example:
# /etc/opt/resmon/lbin/send_test_event disk_em
Events generated by the disk_em monitor are translated into indications
and reported to the CMS. You can view these indications in the Events
List.