HP-UX SysFaultMgmt (System Fault Management) (SFM) Release Notes (766969-001, March 2014) (Edition: 2)

CAUTION: Follow this workaround and proceed with the above mentioned steps, only if the
customers do not want old event data. When you upgrade, diagnostic database is moved
and cannot be viewed using diagnostic utilities (such as Evweb). It cannot be added back
into the original database, due to incompatibility of older PostgreSQL version with the new
version.
Problem:
The Field Replaceable Units (FRU) that are erroneous and marked for deconfiguration, the
health status on HP SMH will not be in synchronization with the health state on the Onboard
Administrator (OA) homepage.
Description:
On HP Superdome 2, the FRU on which errors are found, and Superdome 2 Analysis Engine
has marked them for deconfiguration on the next reboot, the bad health status will not be
reflected on the HP SMH page. This is applicable to HP SMH property pages for processor,
memory and blade FRU's.
Workaround:
Please check the Health Repository on the OA for the latest information on the health of all
the FRU's or alternatively, the OA homepage.
Problem:
Two SysFaultMgmt (System Fault Management) (SFM) processes are running when
SysFaultMgmt (System Fault Management) (SFM) is upgraded . This limitation is not
applicable to the following:
Systems that have SysFaultMgmt (System Fault Management) (SFM) C.07.00.04.06
(March 2010) or later OE release fresh installed.
Systems that have upgraded to SysFaultMgmt (System Fault Management) (SFM)
C.07.00.07.01 (May 2010) or later.
Description:
When SysFaultMgmt (System Fault Management) (SFM) is upgraded from any version prior
to C.07.00.04.06 (March 2010) release to C.07.01.06.01 (September 2010) version, some
systems that have previous events in the database, the cimprovagt process for
SFMProviderModule may consume excessive amount of memory or produce a core dump.
The process list may display two cimprovagt process for SFMProviderModule. One of this
process is orphan and will not monitor hardware(s).
Workaround:
Follow the steps given below before upgrading SysFaultMgmt (System Fault Management)
(SFM) to C.07.01.06.01 version.
Disable SFMProviderModule using the following command:
# cimprovider -dm SFMProviderModule
Problem:
IPMI FRU calls fail when a blade with Monarch Management Processor is inserted into a
different slot.
Description:
On HP Integrity BL860c i2, BL870c i2 & BL890c i2 Server Blades system, when blades are
moved across different slots in an enclosure, the inventory shown by enumerating HP_Blade
or the blade property page on HP SMH does not reflect the correct set of blades on the system.
Workaround:
23