SFM Release Notes for HP-UX 11i v2 March 2013

Core HW (dm_core_hw)
Chassis Code (dm_chassis)
Disk (disk_em)
IPMI Forward Progress Log Monitor (fpl_em)
The following EMS hardware monitors are supported on HP Integrity® servers running the HP-UX
11i v2 operating system:
Corrected platform error monitor (cpe_em)
IPMI forward progress log monitor (fpl_em)
CMC monitor (cmc_em)
Itanium core hardware monitor (ia64_corehw)
SCSI Disk Monitor (disk_em)
Itanium memory monitor (memory_ia64)
Defect fixes
QXCR1001238186
Problem: Memory leak seen in the SFM Provider module due to some log entries in ARCHDB.
Resolution: This problem is fixed.
QXCR1001235076
Problem: The IPMI failure messages are logged in sfm.log during installation.
Resolution: This problem is fixed.
EVWEB
This section describes EVWEB.
What Is EVWEB
EVWEB is a tool that can be used to view and administer WBEM indications generated on the
HP-UX 11i v2 system.
The EVWEB tool includes the following components:
Event subscription administrator
Event subscription administrator enables users to subscribe to an indication and view it. In
addition, users with administrative privileges can also modify, and delete subscriptions. By
subscribing to an indication, users can obtain detailed information about various WBEM
indications.
As a part of event subscription, users must specify event subscription criteria. Users must also
select one or more destinations to receive information about indications.
Users can select one or more destination from the following list:
Event archive: The path of Event archive is /var/opt/sfmdb/pgsql for PA-RISC and
/var/opt/psb/db/pgsql/ for Itanium. Event archive is the default destination.
Email: Event notification will be emailed to the specified email address. Users can specify
multiple email addresses.
Event viewer
The event viewer enables users to view the indications stored in the Event archive. In addition,
users with administrative privileges can also delete these indications. By default, HP-advised
System Fault Management B.07.08.01.01 Release Notes HP-UX 11i v2 March 2013 5