HP Integrity Virtual Machines Installation, Configuration, and Administration Version A.03.50

Table 6-3 Linux Guest Network Installation Screens
ResponseScreen Title
Select your language and enter OK.Language Selection
NFS or FTP and enter OK.Select Installation Method
Type in the guest's IP address and netmask. Enter OK.Network Configuration for eth0
Enter the server name, path to theiInstallation tree, and FTP
parameters (if any).
Request for server parameters
Complete the installation procedure as described in the previous sections.
For information about setting up the network server using the network, see the following Red
Hat website for the appropriate documentation: http://www.redhat.com/docs/manuals/enterprise/
RHEL-4-Manual/en-US/rhel-ig-x8664-multi-en-4/
6.4 Installing SUSE Linux Guests from ISO Images
Before installing the SUSE Linux guest, note the following:
You must install the tog-pegasus RPM kit prior to installing the SUSE Linux RPM guest kit;
however, the SUSE Linux installation media does not contain the tog-pegasus RPM kit. This
RPM kit is available in the “HP Integrity Essentials Foundation Pack for Linux” (also known
as HPIEFL for Linux).
The SUSE Linux RPM guest kit is actually two parts, a guest kit and a provider kit. The
Hpvm.*.rpm kit contains:
Tuning scripts
hpvminfo
hpvmcollect
Guest library
The Hpvmprovider.*.rpm kit contains the VMprovider and related files. This RPM requires
that both the hpvm and tog-pegasus kits must be installed.
http://h20293.www2.hp.com/portal/swdepot/
displayProductInfo.do?productNumber=T2387AA
The information you need is provided in Chapter 5 of the HP Integrity Essentials Foundation
Pack for Linux User's Guide.
To download the HPIEFL for Linux kit, click the link http://www.hp.com/go/
integritylinuxessentials listed in Chapter 5, then click Download for HP Integrity Essentials
Foundation Pack for Linux link on this website.
The first time you install the Linux guest management software, the following error may
occur:
=== from /var/log/messages file ===
Jan 18 22:45:00 1sn000 kernel: ipmi_si: Error clearing flags: cl
=== from "dmesg" command ===
ipmi_si: Error clearing flags: cl
You can ignore this error message.
SLES 10 requires the media to be in the first optical drive present to the guest; otherwise,
the installation fails with the following error:
Failed to initialize the catalog. Try again?
The following steps install SUSE® Linux Enterprise Server (SLES) for HP Integrity servers SLES
10 update 1 guests:
76 Creating Linux Guests