HP Virtual Connect Enterprise Manager 6.2 Release Notes
Table Of Contents
- Table of Contents
- HP Virtual Connect Enterprise Manager Overview
- Supported VCEM components
- Minimum versions of supported platforms
- Enhancements
- Prerequisites
- Issues and workarounds
- Documentation change
- General
- Warning dialogs are not translated into Japanese
- VCEM performance
- Managing VC Domain firmware 3.10 after installing or upgrading to VCEM 6.2
- Resolving removal of the last VC Domain from a VC Domain Group
- Reinstalling Virtual Connect Enterprise Manager
- VC Domain Groups and VC Domain Management
- Jobs
- Server power management
- Server profile operations
- VC Profile Failover
- Profile operations fail, and the error message "An invalid boot LUN was entered. Check the storage arrays for the proper LUN number" appears
- Moving Ethernet networks (VLANs tagged) from one shared uplink to another
- Error popup appears when you select HP predefined ranges during remove VC Domain from Group or delete VC Domain Group operations
- For more information
- Software Availability in Native Languages
3. Click Edit.
4. In the boot target configurations table, change all the target LUN fields to be within the
allowed ranges (either a 3-digit decimal between 0-255, or a 16-digit hexadecimal between
0 and FFFFFFFFFFFFFFFF).
5. Click OK.
6. Monitor the job progress until it is complete.
After the operation completes, you can perform move and failover operations would be server
profile.
Moving Ethernet networks (VLANs tagged) from one shared uplink to another
1. Click the VC Domains tab, and select a VC Domain.
2. Click VC Domain Maintenance, and enable VC Domain Maintenance by clicking Make
changes via VC Domain.
3. In Virtual Connect Manager user interface, delete the desired shared uplink sets or delete
desired Ethernet networks (VLANs tagged) from the shared uplink sets.
4. Go back to VCEM and complete VC Domain Maintenance by clicking Complete VC Domain
Maintenance.
5. Repeat steps 1 and 2.
6. In Virtual Connect Manager user interface, create Ethernet networks (VLANs tagged) to
any shared uplinks set.
7. Go back to VCEM, and complete VC Domain Maintenance by clicking VC Domain
Maintenance.
Error popup appears when you select HP predefined ranges during remove VC
Domain from Group or delete VC Domain Group operations
Using the web browser in Japanese language causes an error popup to appear when you select
a HP Pre-defined range to be used by a VC Domain that is being removed from a VC Domain
Group.
To resolve the issue:
1. Clear the Use Pre-defined range checkbox.
2. Enter the From and To values for the desired range in the text boxes.
3. Click OK. Wait until the process completes.
For more information
For more information about VCEM:
• http://www.hp.com/go/vcem
• HP Insight Software Quick Installation Guide
• HP Insight Software Support Matrix
• HP Virtual Connect Enterprise Manager User Guide
• HP Insight Software VCEM Web Client SDK 6.2 User Guide
For more information about HP Virtual Connect and HP Virtual Connect Manager:
• http://www.hp.com/go/bladesystem
• HP Virtual Connect for c-Class BladeSystem User Guide
• HP Virtual Connect Manager Command Line Interface User Guide
• HP Virtual Connect Release Notes and Compatibility Matrix
For more information about HP Systems Insight Manager:
• http://www.hp.com/go/hpsim
• HP Systems Insight Manager Installation and Configuration Guide for Microsoft Windows
12