HP Virtual Connect Enterprise Manager 6.3 CLI Guide

add fc-connection
The -add fc-connection command adds a new FC connection to a server profile.
Syntax
-add fc-connection profilename <profileName>
-connectionbay <ConnectionBay>
[-fabric <FabricName>]
[-speed <auto|1Gb|2Gb|4Gb|8Gb|disabled>]
Parameters
Table 11 Parameter descriptions for -add fc-connection
OptionalRequiredDescriptionParameter
xThe name of an existing
profile to add the new
connection to.
-profilename
xThe bay for the connection-connectionbay
xThe name of an existing
fabric to associate with the
connection. If the fabric
name is not specified, then
the connection will be
marked as unassigned
but associated with a
specific bay.
-fabric
xThe port speed of the
connection port. Valid values
include auto, 1Gb, 2Gb,
4Gb, 8Gb and disabled.
The default port speed is
auto.
NOTE: For HP 4Gb VC-FC
Modules or HP Virtual
Connect 4Gb FC Modules,
supported speed values
include: auto, 1Gb, 2Gb,
4Gb, and disabled. If it is
set to 8Gb, the speed is
auto-negotiated by VC.
-speed
Output
The function returns the result of the add operation or a jobid if nb is specified.
add fc-connection 33