Table 24 Parameter descriptions for -add server-port-map (continued)
OptionalRequiredDescriptionParameter
xThe name of a valid network
to which the mapping will
be added.
NOTE: A network can be
configured once for every
profile connection and every
profile connection can be
configured for a maximum
of 28 networks.
-network
x
NOTE: If the domain
setting
sharedservervlanid is
set to true, then the
Uplinkset is a required
value.
The name of the shared
uplinkset.
-uplinkset
x
NOTE: If the uplinkset
name is specified, then the
vLanid property should not
be specified, since the server
VLAN ID will be forced to be
same as the VLAN ID used
when adding the network to
the shared uplinkset.
-vlanid
xEnables or Disables the
network to handle untagged
packets. Only one network
in an enet-connection can be
made to handle untagged
packets. The default value is
false.
NOTE: If a shared uplink
set is being used, then the
untagged network is the
same as native network, if
present. However, any other
network can be configured
to handle untagged packets.
-untagged
Output
The function returns the result of the add operation or a jobid if nb is specified.