HP Virtual Connect Enterprise Manager 6.3 CLI Guide

Table 32 VCEM server error messages and descriptions (continued)
Error message descriptionError message number
In the FCoE connection for interconnect bay , the WWN
range type is not compatible with the addresses inside the
connection.
2760
Invalid number of WWN addresses in the FCoE connection
for interconnect bay . VC Domains with multiple logical
HBA ports per physical HBA port support up to 17
WWNN/WWPN pairs per physical port; otherwise, only
one WWNN/WWPN pair is supported per physical port.
2761
In the FCoE connection for port number and interconnect
bay , the specified boot target WWPN is missing or not
well-formed. Valid formats are xx:xx:xx:xx:xx:xx:xx:xx,
xx-xx-xx-xx-xx-xx-xx-xx, or xxxxxxxxxxxxxxxx, where each
x is a hexadecimal digit.
2762
In the FCoE connection for port number and interconnect
bay , the specified boot target LUN is missing or invalid.
Valid values are either a 3-digit decimal between 0 and
255, or a 13- to 16-digit hexadecimal between 0 and
FFFFFFFFFFFFFFFF.
2763
Cannot create FCoE connection because the maximum
number of FCoE connections was reached
2764
Cannot remove FCoE connection because the Server Profile
does not have a FCoE connection
2765
Cannot find FCoE connection for the specified interconnect
bay because the interconnect bay number is invalid or
there is not a FCoE connection for this interconnect bay.
2766
In the FCoE connection for port number and interconnect
bay , the custom port speed exceeds the maximum allowed
port speed ({2}Gb).
2767
In the Ethernet connection for port , the port speed is
incorrect. The minimum and maximum must be the same
when connection speed type is Custom.
2768
VCEM cannot update server profile . The connection bay
was changed.
2769
VCEM cannot update server profile . The connection port
number is duplicated.
2770
There are conflicting boot configuration types defined in
this profile (FC and FCoE). A Server Profile can have only
one boot configuration type specified
2773
There are conflicting boot configuration types defined in
this profile (FC and iSCSI). A Server Profile can have only
one boot configuration type specified.
2774
There are conflicting boot configuration types defined in
this profile (FCoE and iSCSI). A Server Profile can have
only one boot configuration type specified.
2775
A Server Profile does not support more than two configured
Boot Setting parameters in Flex-10 iSCSI connections. The
additional Flex-10 iSCSI connections 'Boot Settings'
parameters must be set to 'Disabled' value.
2776
Cannot perform Server Profile operation because the VC
Domain Group does not support adding iSCSI connections.
2778