HP Virtual Connect 3.75 Release Notes

Important notes 14
HP Integrity i4 Server Blade Version
HP Smart Updated Firmware HP Integrity BL860c/870c/890c i4 System Firmware Bundle for
Linux/Windows (http://h18004.www1.hp.com/products/blades/integrity-release-sets.html)
42.06
HP Integrity Server Blade Version
HP Integrity BL860c
(http://h20000.www2.hp.com/bizsupport/TechSupport/SoftwareIndex.jsp?lang=en&cc=us&pro
dNameId=3351095&prodTypeId=3709945&prodSeriesId=3331044&swLang=13&taskId=135&
swEnvOID=4001)
04.31
HP Integrity BL870c
(http://h20000.www2.hp.com/bizsupport/TechSupport/DriverDownload.jsp?lang=en&cc=us&pr
odNameId=3676869&taskId=135&prodTypeId=3709945&prodSeriesId=3676868&lang=en&cc
=us)
04.31
Important notes
When connecting a Virtual Connect FlexFabric 10Gb/24-port Module directly to 3PAR storage systems
in the VC multi-enclosure environment, a server profile migration of a SAN-booted server between
enclosures is not supported. Similarly, in the domains managed by Virtual Connect Enterprise Manager
(VCEM), a server profile migration of a SAN-booted server between enclosures within the same Domain
Group or between different Domain Groups is not supported.
To perform a server profile migration of a SAN-booted server between enclosures directly attached to
a 3PAR storage system in the VC multi-enclosure environment, the following manual steps are required:
a. Power off the server.
b. Un-assign the server profile.
c. Change the Primary and Secondary Target WWNs in the FC Boot Parameters section of the profile
to reflect the WWNs of the 3PAR storage array ports directly connected to the destination
enclosure.
d. Assign the profile to the destination location.
e. Power on the destination server.
Although the GUI enables the selection of SNMP v2 traps, the VC 4Gb FC Module and the VC 8Gb
20-Port FC Module remain as v1 traps.
Changes in the server RBSU can override Virtual Connect server profile settings for PXE (enabled or
disabled). If you make a change in RBSU, that change is not reflected in Virtual Connect Manager. If
you set PXE through RBSU, HP recommends using the "Use-BIOS" setting.
Related information
Virtual Connect Enterprise Manager support