HP Virtual Connect Manager Command Line Interface for c-Class BladeSystem Version 4.01 User Guide

Command line 28
Item Description
->set domain MacType=User-Defined MacStart=00-17-A4-77-00-00
MacEnd=00-17-A4-77-00-FF
Sets the MAC address source to a custom, user-defined address range
->set domain WwnType=VC-Defined WwnPool=5
Sets the WWN address source to VC-Defined with a pre-defined range
->set domain WwnType=Factory-Default
Sets the WWN address source to use factory default WWN addresses
->set domain WwnType=User-Defined
WwnStart=50:06:0B:00:00:C2:62:00
WwnEnd=50:06:0B:00:00:C2:62:FF
Sets the WWN address source to a custom, user-defined address range
->set domain SingleDense=true
Sets the display option to support single-dense servers in a double-dense supported
configuration
Item Description
show domain
Display general Virtual Connect domain information, including the Virtual Connect
domain name, the VCM domain IP address settings, and MAC/WWN address
settings for the domain.
Syntax
show domain [addressPool]
Parameter
addressPool
(Optional)
Displays all VC-defined address pool ranges available for use
Examples
->show domain
Displays domain information
->show domain addressPool
Displays the VC-defined address pool ranges available for use
enclosure
Manage general enclosure settings and information.
Supported actions: help, import, remove, show
Item Description
import enclosure
Import local and remote enclosures into the Virtual Connect domain. Virtual
Connect supports up to four c7000 enclosures in a single domain.
Syntax
import enclosure [<IPv4Address|DNSname>]
[UserName=<username>] [Password=<password>]
[DoubleDense=<True|False>]
For enclosures that are not imported, the password field is optional. If not
specified, the system interactively prompts you for the password.
Parameter
IpAddress (Optional)
The IPv4 address or DNS name of the remote enclosure to be imported. If not
specified, the local enclosure is assumed.
Option
quiet
This option suppresses user confirmation prompt while importing a remote
enclosure, and is typically used in automated scripting scenarios.
Properties
UserName (Required for
A valid user name with access to the Onboard Administrator for the enclosure to