HP Virtual Connect Manager Command Line Interface Version 3.00 User for Integrity BL8x0c i2 Server Blades Guide

Command line 46
Item Description
configured properly before port monitoring can be enabled.
AnalyzerPort
(optional)
The uplink port used for monitoring network traffic. The format of the network
analyzer port is <EnclosureID>:<InterconnectBay>:<PortNumber>.
If the enclosure ID is not specified, the default enclosure is the local enclosure.
Speed (optional)
The port speed for the network analyzer port. Valid values include "Auto",
"10Mb", "100Mb", "1Gb", "10Gb", and "Disabled". The default value is
"Auto".
If there is no connector present on the analyzer port, only "Auto" and
"Disabled" can be configured as a possible speed. Speed restrictions apply.
Duplex (optional)
The port duplex mode of the network analyzer port. Valid values include
"Auto", "Half", and "Full". The default value is "Auto".
MonitorPort
(required if the
Direction property
is being modified)
The server port to be monitored. The format of the monitored port is
<EnclosureID>:<DeviceBay>:<PortNumber>.
If the enclosure ID is not specified, the default enclosure is the local enclosure
where the domain resides.
Direction
(optional)
The direction of network traffic on the port being monitored. Valid values
include "ToServer", "FromServer", and "Both".
Examples
->set port-monitor AnalyzerPort=enc0:3:1 Speed=1Gb
Duplex=half
Modifies network analyzer uplink port properties
->set port-monitor MonitorPort=enc0:1:6
Direction=ToServer
Modifies a monitored server port
->set port-monitor Enabled=true
Enables port monitoring
->set port-monitor Enabled=false
Disables port monitoring
Item Description
show port-monitor
Display the Virtual Connect port monitor configuration.
Syntax
show port-monitor
Example
->show port-monitor
Displays the port monitor configuration
profile
Manage server profiles.
Supported actions: add, assign, help, remove, set, show, unassign
Item Description
add profile
Create a new server profile. After the profile has been created, the profile can
then be configured using the "set" subcommand, and the additional network,
fabric, and FCoE connections can also be added. The server profile can also be