HP Virtual Connect Version 2.33 Release Notes

New features 9
New features
The VC 2.33 release has no additional new features.
The VC 2.32 release has no additional new features.
The VC 2.31 release has no additional new features.
The VC 2.30 release includes the following new features:
Support for the HP Virtual Connect 8Gb 20-Port Fibre Channel Module. 8Gb configuration and
operation is supported only by G6 servers.
The following SNMP enhancements:
o Added limited extensions to already supported MIBs
o Added SNMP traps for Ethernet port state changes
o Added SNMP traps for key, pre-defined threshold conditions
o Supports new MIBs and traps for key VC domain and module elements
o Supports both SNMPv1 and SNMPv2 traps (by trap destination)
Trap destinations
Type of traps to be sent to the destination
Levels of traps to be sent to the destination
Type and class of trap to be sent
New module and domain MIBs. For additional information, see the VCM user guide.
This feature does not include user configuration of trap thresholds.
Increased the maximum number of VLANs allowed for an uplink port (or port set) from 64 to 128.
Support for BL495c G6 and BL465c G6 server blades.
Support for the new HP Code Signing Process.
Support the ability to connect two VC domains together (single enclosure or multi-enclosure) by
directly connecting their uplinks (no switch in between) to form a private network.
Added support for dynamic changes to FlexNICs. Servers no longer need to be powered off to
change the following FlexNIC settings:
o bandwidth
o link state
o network/VLAN assignment
FlexNIC link state is now accurately reported in the VCM GUI.