HP XC System Software Hardware Preparation Guide Version 3.1

Table 3-1 Firmware Dependencies (continued)
Firmware DependencyHardware Component
MP, BMC, EFI, systemHP Integrity rx4640
MP, BMC, EFI, systemHP Integrity rx8620
Switches
Firmware versionProCurve 2824 switch
Firmware versionProCurve 2848 switch
Firmware versionProCurve 2650 switch
Firmware versionProCurve 2626 switch
Interconnect
Firmware versionMyrinet
Interface card versionMyrinet interface card
Firmware versionQsNet
II
Firmware versionInfiniBand
1 Dual core
3.2 Ethernet Port Connections on the Head Node
Table 3-2 lists the Ethernet port connections on the head node based on the type of interconnect in use.
Use this information to determine the appropriate connections for the external network connection on the
head node.
IMPORTANT: The Ethernet port connections listed in Table 3-2 do not apply to HP XC systems with HP
server blades and enclosures.
For more information, see the HP XC Systems With HP Server Blades and Enclosures HowTo, which is available
at the following Web site:
http://www.docs.hp.com/en/highperfcomp.html
Table 3-2 Ethernet Ports on the Head Node
All Other Interconnect TypesGigabit Ethernet Interconnect
Physical onboard Port #1 is always the connection to the
Administration Network.
Physical onboard Port #2 is available for an external
connection if needed (except if the port is 10/100, then it is
unused).
Add-on NIC card #1 is available for an external connection
if Port #2 is 10/100.
Physical onboard Port #1 is always the connection to the
Administration Network.
Physical onboard Port #2 is the connection to the interconnect.
Add-on NIC card #1 is available as an external connection.
3.3 General Hardware Preparations for All Cluster Platforms
Make the following hardware preparations on all cluster platform types if you have not already done so:
1. The connection of nodes to ProCurve switch ports is important for the automatic discovery process.
Ensure that all nodes are connected as described in “Making Node and Switch Connections” (page 19).
2. Ensure that switches are configured to obtain IP addresses using DHCP. For more information on
how to do this, see the documents that came with the ProCurve hardware. ProCurve documents are
also available at the following Web page:
http://www.hp.com/go/hpprocurve
3. Ensure that any nodes connected to a Lustre® file system server are on their own Gigabit Ethernet
switch.
32 Preparing Individual Nodes