HP XC System Software Installation Guide Version 4.0

Info: Starting transfer of services to ServiceGuard...
prepForAvail:
==========
Executing 'pdsh -S -w n7 '/opt/hptc/etc/nconfig.d/C50nat nxferto n7''...
pdsh@n8: n7: RC=0
prepForAvail:
==========
'pdsh -S -w n7 '/opt/hptc/etc/nconfig.d/C50nat nxferto n7'' finished, exited with 0(0)
prepForAvail:
========== Executing 'pdsh -S -w n8 '/opt/hptc/etc/nconfig.d/C50nat nxferto n8''...
pdsh@n8: n8: RC=0
prepForAvail:
==========
'pdsh -S -w n8 '/opt/hptc/etc/nconfig.d/C50nat nxferto n8'' finished, exited with 0(0)
prepForAvail:
==========
Executing '/opt/hptc/etc/nconfig.d/C12dbserver nxferto n8'...
Stopping MySQL: [ OK ]
my.cnf 100% 287 0.3KB/s 00:00
prepForAvail:
==========
'/opt/hptc/etc/nconfig.d/C12dbserver nxferto n8' finished, exited with 0(0)
startAvailTool:
==========
Executing '/opt/hptc/availability/serviceguard/start_avail'...
Configuring HP Serviceguard cluster [-C
/usr/local/cmcluster/conf/avail1.config -P
/usr/local/cmcluster/conf/nat.n7/nat.n7.config -P
/usr/local/cmcluster/conf/nat.n8/nat.n8.config -P
/usr/local/cmcluster/conf/lvs.n8/lvs.n8.config -P
/usr/local/cmcluster/conf/nagios.n8/nagios.n8.config -P
/usr/local/cmcluster/conf/dbserver.n8/dbserver.n8.config ].
Applying the cluster configuration.
Begin cluster verification...
Warning: No additional packages can be added to this cluster.
Adding node n7 to cluster avail1.
Adding node n8 to cluster avail1.
Completed the cluster creation.
Starting the cluster.
cmruncl : Validating network configuration...
cmruncl : Network validation complete
cmruncl : Waiting for cluster to form....
cmruncl : Cluster successfully formed.
cmruncl : Check the syslog files on all nodes in the cluster
cmruncl : to verify that no warnings occurred during startup.
startAvailTool:
==========
'/opt/hptc/availability/serviceguard/start_avail' finished, exited with 0(0)
Info: Successful transfer of services to Serviceguard.
After services and IP aliases are shut down, each availability tool is started. Then, the availability
tool starts up the services and IP aliases it is managing.
7.5 Configuring SNMP Trap Destination for Enclosures
Perform this task only if the hardware configuration contains enclosures.
If the hardware configuration contains enclosures, HP recommends that you configure the
enclosures to send their SNMP traps to the management server IP alias.
After doing so, all SNMP traps are processed by the snmptrapd service and subsequently logged
to syslog by the snmptt service. The syslog-ng service logs all traps to the /hptc_cluster/
adm/log/consolidated.log file and the /hptc_cluster/adm/logs/snmptraps.log
file.