HP P9000 Command View Advanced Edition Suite Software 7.3.1-00 CLI Reference Guide

DescriptionStatusParameter name
Starting sequence number of parity groups for which information
is to be obtained
Specify this parameter when you want to obtain information for
a part of parity groups in a specific storage system.
When parity group information is ordered as shown below and
numbered from 0 upward, specify the first number in the sequence
of parity groups that you want to obtain.
Order of parity groups:
1. Chassis numbers in ascending order
2. Parity group numbers in ascending order
This parameter must be specified together with the
numOfElementsFilter, model, and serialnum parameters.
Optional
startElement-
NumFilter
Number of parity groups for which information is to be obtained
Specify this parameter when you want to obtain information for
a part of parity groups in a specific storage system. Specify the
number of parity groups for which information is to be obtained.
This parameter must be specified together with the
startElementNumFilter, model, and serialnum
parameters.
The maximum recommended value is 16384.
Optional
numOfElements-
Filter
Parity group name
The following value specification formats can be used:
n
n - n
n - n - n
E n - n
V n -1
X n -1
Here, n is an integer of 1 or greater, while E, V, and X are fixed.
If this parameter is specified, the model parameter must also be
specified.
Optional
arraygroupname
Parameter values to obtain in advance
serialnum and model
Obtain these values from the execution result of the GetStorageArray command. In the execution
result, use the arrayType value or the displayArrayType value to specify the model para-
meter, and use the serialNumber value to specify the serialnum parameter.
Command execution example 1
In this example, the GetStorageArray (subtarget=ArrayGroup) command obtains information
about parity groups in a storage system (serial number: 14010, model: XP12000).
hdvmcli GetStorageArray -o "D:\logs\GetStorageArray_ArrayGroup.log"
subtarget=ArrayGroup model=XP12000 serialnum=14010
Command reference126