HP P9000 Command View Advanced Edition Suite Software 7.3.1-00 CLI Reference Guide

cacheResidencyMode=-1
stripeSizeInKB=-1
volumeKind=3
status=Blocked
thpType=-1
consumedSizeInKB=-1
mfTrueCopyVolumeType=Unknown
mfShadowImageVolumeType=Unknown
mfUniversalReplicatorVolumeType=Unknown
mfUniversalReplicatorPoolID=-1
thpPoolID=-1
threshold=-1
systemDisk=0
encrypted=-1
tieringPolicy=-1
*****: The values are encoded by the CLI.
Command execution example 2
hdvmcli AddLun -o "D:\logs\AddLun.log" "serialnum=10001" "model=XP1024"
"name=hp" "port=1" "domain=4" "scsi=15" "lun=120" "devnum=1006"
Command execution result 2
RESPONSE:
An instance of StorageArray
.
. (Attributes of StorageArray are omitted here)
.
List of 1 Path elements:
An instance of Path
objectID=*****
name=hp
devNum=1,006
displayDevNum=03:EE
portID=1
portName=CL1-B
domainID=4
scsiID=15
LUN=120
wwnSecurityValidity=true
*****: The value is encoded by the CLI.
AddWWNForHostStorageDomain
AddWWNForHostStorageDomain assigns a WWN to a host storage domain LUN to sets up LUN
security.
CLI Reference Guide 231