HP P9000 Command View Advanced Edition Suite Software 7.3.1-00 CLI Reference Guide

DescriptionStatusParameter name
New domain ID of the path
Omit this when no change is required.
This parameter can be specified in decimal and hexadecimal. If
you specify a hexadecimal number, add the 0x prefix.
The execution results are output in decimal.
Optional
domain
New device number of the path
Omit this when no change is required.
For P9500 and XP24000/XP20000:
Specify this parameter as a decimal number or colon-delim-
ited hexadecimal number in the format ww:xx:yy, where
ww is the LDKC number, xx is the CU number, and yy is the
LDEV number. ww is optional. If ww is omitted, LDKC is as-
sumed to be 0.
For XP12000/XP10000/SVS200 and XP1024/XP128:
Specify this parameter as a decimal number or colon-delim-
ited hexadecimal number in the format xx:yy, where xx is
the CU number, and yy is the LDEV number.
The execution results are output in decimal.
Optional
devnum
New Port WWN on the host bus adapter
Omit this when no change is required.
Optional
portwwn
New type of the file system
Omit this when no change is required.
Optional
filetype
New name of the file system
Omit this when no change is required.
Optional
filename
New LUN size in MB
Omit this when no change is required.
Optional
size
New percentage of the LUN in use
Omit this when no change is required.
Optional
percentused
Parameter values to obtain in advance
serialnum and model
Obtain these values from the execution result of the GetStorageArray command. In the execution
result, use the arrayType value or the displayArrayType value to specify the model para-
meter, and use the serialNumber value to specify the serialnum parameter.
objectid
Obtain this value from the execution result of the GetHostInfo command. In the execution result
of this command, the objectID value appears under An instance of HostInfo. Use this
objectID value to specify the objectid parameter.
devnum, domain, and port
Obtain these values from the execution result of the GetStorageArray (subtarget=Path)
command. Execute this command by specifying only the model and serialnum parameters,
and Path for the subtarget parameter. In the execution result of this command, the devNum,
Command reference270