HP P9000 Command View Advanced Edition Suite Software 7.3.1-00 CLI Reference Guide

Description and recommended actionProblem
CAUSE: The host used for creating the copy pair recognizes CL1-A
or LUN0.
SOLUTION: Assign another port to the LU or assign a LUN other
than LUN0, and re-create the copy pair.
SOLUTION: Collect the following information, and then contact
your HP Technical Support representative.
CLI log file
CLI properties file
Command line input
An executed batch file if a batch was executed.
Device Manager server log.
The following error message is displayed
and the Device Manager CLI stops:
An unspecified error was
encountered in CLI.
CAUSE: A maximum of 256 characters can be displayed for the
main body of an error message.
SOLUTION: Check the omitted content in the CLI log file.
Text is omitted from the displayed error
message.
CAUSE: The configuration in the Device Manager database is
inconsistent with the configuration of the actual storage system
information.
SOLUTION: Use the AddStorageArray command to refresh the
storage system information. Verify that the value of
statusOfDBInconsistency indicated below An instance
of StorageArray in the command execution results is 0, and
then re-execute the command.
The following message is displayed when
a Device Manager CLI command is
executed:
[KAIC07472-E] The storage
system information ("storage
system-name") is inconsistent.
Refresh the storage system,
and then try again.
Troubleshooting424