HP P9000 Command View Advanced Edition Suite Software 7.3.1-00 CLI Reference Guide

For details, see the documentation of the LUN management product for the storage system you are
using.
Table 23 Values that can be specified in the hostmodeoption parameter
XP12000/
XP10000/
SVS200
XP24000/
XP20000
P9500Description
hostmodeoption
values
YYY
VERITAS Database Edition/Advanced
Cluster
Specify this value when using VERITAS
Database Edition/Advanced Cluster
for Real Application Clusters or
VERITAS Cluster Server 4.0 or later
(I/O fencing feature).
2
YYY
TPRLO
Specify this value when all of the
following conditions are satisfied:
The host mode is set to Windows
(mode 0C) or Windows Exten-
sion (mode 2C).
An Emulex host bus adapter is in
use.
A mini-port driver is in use.
The TPRLO parameter for the mini-
port driver of the host bus adapter
is set to 2.
6
YYY
Automatic recognition function of LUN
Specify this value when both of the
following conditions are satisfied:
The host mode is set to Standard
(mode 00) or Solaris (mode
09).
You want to let the system automat-
ically recognize the reduction and
increase in the number of devices
when a SUN host bus adapter is
in use.
7
YYY
No display for ghost LUN
Specify this value when both of the
following conditions are satisfied:
The host mode is set to HP (mode
03).
You want to prevent devices to
which no paths have been defined
from creating a device file when
the HP-UX host is connected.
12
Command reference54