HP P9000 Command View Advanced Edition Suite Software 7.3.1-00 Release Notes

Table Of Contents
Changing the CHA/DKA status
Changing the cache status
Replacement of an OEM drive microcode
LDEV shredding
If this occurs, format the blocked pool volumes by using the CLI FormatLU command, or Element
Manager.
Displaying volume capacity in the Create Volumes dialog box
The specified volume capacity may not be displayed correctly in the plan screen of the Create Volumes
dialog box.
If this occurs, see the task list to confirm the correct capacity.
Displaying the Unallocate Volume dialog box
The volume capacity shown in the plan screen of the Unallocate Volume dialog box may be incorrect.
If this occurs, see the task list to confirm the correct capacity.
Allocate Volumes and Allocate Like Volumes for a storage port with LUN Security disabled
In the Allocate Volumes dialog box and Allocate Like Volumes dialog box, when you choose Allocate
without LUN Security for a target host, the volume is allocated to the host by using the minimum
available LU number. Even though the LU number candidate is chosen with auto or manual in LU
Number, the candidate might not be used.
If you need to use a specific LU number for a volume, use Remote Web Console.
Setting, changing, and deleting remote path information using storage management
tools other than Device Manager
When remote path information is set, changed, or deleted using storage management tools other than
Device Manager, if storage systems related to the remote path information are refreshed simultaneously,
Device Manager might recognize the remote path information incorrectly.
If this occurs, refresh these storage systems sequentially.
At this time, the following symptoms occur in the Device Manager CLI.
Remote path information is incorrect in the GetReplicationControllerPair command
output.
If the remote path information is incorrect in the storage system specified by the AddReplication
command, the command generates the KAIC90083-E error (error code= 7929).
Volume list filtering
An error occurs when the following columns are selected in the filter for the volume list.
Copy Info (P-VOL) and Copy Info (S-VOL)
Volume Attribute and Storage System
Volume Attribute and Copy Info (P-VOL)
Volume Attribute and Copy Info (S-VOL)
Volume Attribute and Pool
Storage system deletion
When deleting storage systems, delete each storage system sequentially.
Important considerations 13