HP P9000 Command View Advanced Edition Suite Software 7.3.1-00 Release Notes

Table Of Contents
Method change for variation detection in an XP P9500
If the server.dispatcher.daemon.configUpdate.detection.variable.enabled property
in the dispatcher.properties file is set to false (default value for 7.3.0 or later), the following
XP P9500 configuration variations are not detected:
Usage rate of THP volumes
Usage rate of THP pools, Smart pools, or Snapshot pools
Threshold value for the usage rate of THP pools, Smart pools, or Snapshot pools
Subscription limit capacity of THP pools, Smart pools, or Snapshot pools
Monitoring mode of Smart pools
Setting for performance monitoring or relocation of Smart pools
To enable the detection, change the property value to true.
NOTE: If the property is changed, restart services or daemons of XP Command View Advanced
Edition Suite products.
Smart monitoring schedule template view
In versions of Device Manager 7.3.0-00 or later, the Smart monitoring schedule template view changed
to the Sunday calendar style.
CLI copy pair operation error 6119
A CLI copy pair operation may generate the error code 6119. If this occurs, check the following items.
Check the version of RAID Manager or RAID Manager XP that supports the required operation.
Check that RAID Manager or RAID Manager XP is properly installed.
If this does not solve the problem, collect maintenance information and contact HP Technical Support.
KAIC16902-E message with no summary information in the main window during any
operation in the GUI
During any operation in the GUI, the KAIC16902-E message appears in the top window and the
Summary information does not appear in the main window.
If this occurs, close the error dialog box and continue the operation. If you need the summary
information, log in to Device Manager again.
Number of external paths
When the external volume is being directly assigned to the host from the external storage system, the
number of external paths appearing on the external volume tab of the storage system does not match
the number of external paths displayed in Remote Web Console.
Check the number of external paths in Path Information in the Detailed Information window.
Mapping of Available External Volumes
In the GUI, the Available External Volumes created with one of the following volumes cannot be
mapped to Internal Volumes.
Volumes created when the volume virtualization task in the GUI did not succeed by interception.
Volumes in the external storage system allocated to the internal storage system by the CLI AddLun
command.
Volumes in the external storage system allocated to the internal storage system by Element Manager,
XP P9000 Remote Web Console, or XP Remote Web Console.
Important considerations 15