HP P9000 Command View Advanced Edition Suite Software 7.4.0-00 Administrator Guide (web) (TB581-96325, December 2012)

Table Of Contents
SolutionProblem and causeNo.
3. If there are LDEVs that have not been migrated yet, re-
move the cause of the error, and then re-create and
execute the migration task.
Restore a backed up database.
PROBLEM: Tiered Storage Manager
operations cannot be performed
because an error occurred in the
database.
CAUSE: The repository cannot be
accessed because an error occurred
in the database.
4
Problems and solutions in the host
The following table lists common problems that occur on the Device Manager agent and describes
how to resolve them.
Table 113 Common problems and solutions on the Device Manager agent
SolutionProblemNo.
This message is output when multiple HiScan commands
are executed at the same time.
No action is required.
The following message was output to
the event log or the system log:
[HORCM_005] Could not
create endpoint for remote
connection.
1
The following message was output to
the event log or the system log:
[HORCM_007] Illegal
parameter values in HORCM
configuration file.
2
The LUN path to the volume managed by the Device Man-
ager recognized by the host has been disabled, possibly
due to a lost connection. Either restore the disabled LUN
path, or change the OS settings so that the disabled LUN
path is no longer recognized.
When executing the HiScan com-
mand, the KAIC22019-E error mes-
sage is output, and host information
cannot be registered on the Device
Manager server.
3
Another P9000 Command View AE Suite product might
have attempted to access the Device Manager agent either
immediately after the installation of the Device Manager
agent was complete, or immediately after the Device Man-
ager agent services started. Wait a few minutes, and then
retry the operation.
A communication error occurs, and
the processing of other P9000 Com-
mand View AE Suite products stops.
4
Troubleshooting286