The volume pairs excluded from Device Manager operations are also excluded from Replication
Manager operations. To specify multiple instance numbers, separate the individual numbers with
commas (,). From the Device Manager agent, you cannot operate a RAID Manager whose instance
number is specified in this property.
Default: None
server.agent.rm.location
Specify the RAID Manager installation directory if RAID Manager is installed in a location other than
the default or if the host OS is Windows and the RAID Manager installation drive is different from the
Device Manager agent installation drive.
For Windows, you cannot specify \ as a delimiter. Use \\ or / instead.
Default for Windows: drive-where-Device-Manager-agent-is-installed/HORCM
Default for UNIX: /HORCM
server.agent.rm.optimization.userHorcmFile
Specify whether to optimize the user-created RAID Manager configuration definition files.
To optimize the file, specify true. If you do this, the file is updated so that Device Manager can use
it. Also, when the Device Manager agent starts or when the configuration definition file is updated
by pair operations, the following optimizations are performed:
The unit ID, LDEV number, and serial number of a command device are added as comments.
If the above command device becomes unavailable due to, for example, a change to the volume
name, the configuration definition file information is updated so that the command device can be
used.
If the host is connected to multiple command devices in a storage system and only some of those
command devices are specified, the rest of the command devices are specified as reserved com-
mand devices.
Command devices that are not being used are deleted.
The CU and LDEV numbers of a command device and pair volume are added as a comment in
the format cu:ldev.
If there are multiple definitions for a command device of the same storage system in an SLPR en-
vironment, rearrange the order of the command device definitions.
Apply the value specified in the server.agent.rm.horcm.poll property to poll of the
HORCM_MON parameter in the configuration definition file.
Default: false
server.agent.rm.horcm.poll
Specify the value defined for poll of the HORCM_MON parameter in the configuration definition file
(the monitoring interval for copy pairs) in hundredths of a second.
If monitoring is not being performed, specify -1.
The value specified for this property is applied to the configuration definition file at the following
times:
When a pair is created or added
When the configuration definition file is optimized
Administrator Guide (Web Version) 413