HP P9000 Replication Manager Software 7.3.1-00 User Guide

P9000 RAID Manager
Description
Change Pair Status Wizard
OptionCommandOptionOperation
n/aExecute these
commands in the
following order:
1. pairsplit
2. pairresync -
swaps
Redirects copying, retaining the
current copy pair state.
None
swap
-c size
Copy Pace
n/a
pairresync -swaps
Recovers an S-VOL from the
Split(SSWS) status and the P-VOL
and S-VOL to the Pair(PAIR) status.
None
takeover-recov-
ery (resync)
-c size
Copy Pace
n/a
Execute these
commands in the
following order:
1. pairsplit -R
2. pairsplit -S
3. paircreate
Note: Items in the
Option column for this
operation apply to the
paircreate
command only.
Recovers the P-VOL and S-VOL to
the Pair(PAIR) status when the P-
VOL is in the Simplex(SMPL) status
and the S-VOL is in the Split(SS-
WS) status.
None
takeover-recov-
ery (recreate)
-c size
Copy Pace
-f fence
[CTGID]
where fence
= "data",
"status",
"never",
"async"
Fence Level
-jp id
JNLG ID(P)
-js id
JNLG ID(S)
-nocopy
No Copy
Monitoring and managing storage systems using virtual
command devices
As an alternative to using P9000 RAID Manager command devices, you can also issue commands
to storage systems over the LAN connection using virtual command devices.
NOTE:
As of 7.1.0, Replication Manager only supports monitoring and managing copy pair configuration
definitions that use virtual command devices. You cannot set up such a configuration from within
Replication Manager.
This module includes the following topics:
About virtual command devices, page 241
Prerequisites for virtual command device configurations, page 242
Setting up an SVP as a virtual command device , page 243
Using a Virtual Command Device server, page 244
If a virtual command device fails to call the Device Manager Agent, page 245