When you specify the -cascade option, a backup catalog is automatically transferred to a backup
server defined in the cascade configuration information definition file. The backup catalog is transferred
to a backup server on both the local site and the remote site.
-auto_mount mount-point-directory-name
Specify this option to automatically mount a secondary volume on a backup server after completing
a volume backup. This option must be specified concurrently with either the 1 or 2 option.
1. The -s and -auto_import options
2. The -cascade and -auto_import options
Specify mount-point-directory-name by using no more than 64 bytes of characters.
If you omit mount-point-directory-name, a mount destination for a secondary volume is automatically
specified. Apply the same rule as when a mount point is not explicitly specified in the drmmount
command.
To unmount the mounted secondary volume, use the drmumount command.
-svol_check
Specify this option to check the status of a secondary volume on a backup server. This option must
be specified concurrently with the -s option. Checking the status of a secondary volume prevents
backup or restoration failures. Items, targets, and conditions to be checked are as follows:
Table 45 Status check of a secondary volume
Check conditions
Volume to be
checked
Check items
Checked when a primary volume is defined in pairs with
multiple generations of secondary volumes and if either of the
following items is applicable:
A primary volume is a cluster resource.
A primary volume is a dynamic disk.
A backup using VSS is performed.
All secondary
volumes defined for
a backup-target
primary volume
A secondary volume
is hidden from a
backup server
Always checked.
A secondary volume
to be the next backup
destination
A secondary volume
is not mounted on a
backup server
This option must not be specified concurrently with the -cascade option.
-cascade
Specify this option to perform a backup on both the local site and remote site concurrently when
configuring a cascade.
After the backup finishes, a backup catalog is registered on the local site and remote site respectively.
The same copy group and MU# of the local site is also used on the remote server.
You cannot specify this option concurrently with the following options:
-s
-pf
-svol_check
If you specify the -rc option concurrently with this option, and the generation identifier specified in
the -rc option and the generation number at the remote side are different, an error occurs.