HP StorageWorks P9000 Command View Advanced Edition Suite Software 7.1.1 Administrator Guide (web) (TB581-96065, September 2011)

DescriptionParameter
Device numbers of expired volumes
Example:
3:A6
expiredVolumes
Scheduled time when an "elapsed time" event will
occur
Example:
2007/03/25 17:00:00
remindAt
Message that appears when an "elapsed time" event
occurs
Example:
It is scheduled to move.
reminderDescription
Note:
For details, see the HP StorageWorks P9000 Tiered Storage Manager Software CLI Reference
Guide.
Specifying SMTP user authentication information for event notification
The event notification functionality establishes a connection with the SMTP server. To use SMTP
authentication for the connection, an SMTP authentication user account must be set up in the Device
Manager server by using the hdvmmodmailuser command.
TIP:
To send notifications about executed tasks via the Tiered Storage Manager CLI or the Tiered Storage
Manager GUI in Legacy mode, an SMTP authentication user account must be set up on the Tiered
Storage Manager server by using the htsmmodmailuser command.
Format of the hdvmmodmailuser command
The SMTP authentication user settings set by the hdvmmodmailuser command are also used for
alert email notification. If an SMTP authentication user has already been set for alert email notification,
then these settings are not required here.
The following is the syntax of the hdvmmodmailuser command:
Format
In Windows:
installation-folder-for-the-Device-Manager-server\Server\tools\hdvmmod-
mailuser.bat -u Device-Manager-user-ID -p Device-Manager-password SMTP-
authentication-user-ID [SMTP-authentication-password]
In Linux:
installation-directory-for-the-Device-Manager-server/Server/tools/hd-
vmmodmailuser.sh -u Device-Manager-user-ID -p Device-Manager-password
SMTP-authentication-user-ID [SMTP-authentication-password]
Options
Administrator Guide (Web Version) 139