HP StorageWorks P9000 Command View Advanced Edition Suite Software 7.1.1 Administrator Guide (web) (TB581-96065, September 2011)

We recommend that use the same computer for the management server and for the host that ac-
quires performance information. In this case, the OS for the host that acquires performance in-
formation must be able to support both Device Manager server and the Device Manager agent.
For example, if the OS for the management server is Windows XP, you cannot install the Device
Manager agent, so you cannot use this computer as the host that acquires performance information.
Even if you use different computers for the management server and for the host that acquires
performance information, the OS for the host that acquires performance information must be
Windows, or Linux.
The host that acquires performance information cannot run HP-UX or AIX.
We recommend that you use the hdvmagt_setting command to set the Device Manager agent
central management method.
Storage system
This is a storage system whose performance information is to be acquired.
The host that acquires performance information (the Device Manager agent) acquires the inform-
ation of P9500, XP24000/XP20000 and XP12000/XP10000/SVS200 by using the command
device within the storage system, and then reports it to the Device Manager server.
The system configuration that is required to acquire performance information of a storage system
differs depending on the storage system model.
For information on P9500, XP24000/XP20000 or XP12000/XP10000/SVS200, see Acquiring
performance information from P9500, XP24000/XP20000 or
XP12000/XP10000/SVS200 on page 154.
Acquiring performance information from P9500, XP24000/XP20000 or
XP12000/XP10000/SVS200
This section describes the settings required to acquire performance information for P9500,
XP24000/XP20000 or XP12000/XP10000/SVS200 storage systems.
Preparing the storage system for acquiring performance information
Prepare a command device for each storage system from which you want to acquire performance
information, and then assign a path to the host that will acquire the performance information so that
the host can recognize the command device.
To acquire P9500 performance information, force hosts to recognize command devices for which
authentication mode is disabled.
Preparing the host to acquire performance information
Configure the settings shown below for the host that will acquire performance information.
Configuring Device Manager for CIM/WBEM154