HP StorageWorks P9000 Command View Advanced Edition Suite Software 7.1.1 Administrator Guide (web) (TB581-96065, September 2011)

Specify a value from 0 to 30. We recommend that the default value be used. Note that the same
messages are output whether you specify 20 or 30, because there are no messages whose output
level is 30.
Default: 20
The output levels are based on the contents of the logged messages. The following table shows the
output levels of message log data.
Table 133 Output level of message log data
Message descriptionsOutput levelType of message
An error occurred that affects the operation of the management
server or Java servlet.
0
Error
An execution error occurred due to a reason such as an operational
mistake.
10
An error occurred, but execution can continue with limitations.20
Warning
Information has been produced about the actions of the management
server and the GUI.
0
Information
Information has been produced about the processing for an opera-
tion.
20
CAUTION:
If you have changed the property value, restart the services of P9000 Command View AE Suite
products to enable the new value.
logger.tracelogLevel
This setting specifies a threshold output level for the trace logging by Tiered Storage Manager. This
property applies to the Tiered Storage Manager server trace log (HTSMServerTracen.log) and
the GUI trace log (HTSMGuiTracen.log).
Messages with an output level equal to or lower than the level specified in this property will be written
to the trace log.
Specify a value from 0 to 30. We recommend that the default value be used.
Default: 20
Output levels are based on the contents of the logged messages. The following table shows the output
levels of trace log data.
Table 134 Output level of trace log data
Message descriptionsOutput levelType of message
An error occurred that affects the operation of the management
server or Java servlet.
0
Error
An execution error occurred due to a reason such as an operational
mistake.
10
Tiered Storage Manager server properties344