HP StorageWorks P9000 Command View Advanced Edition Suite Software 7.1.1 Administrator Guide (web) (TB581-96065, September 2011)

The following table describes the port numbers that must be registered as firewall exceptions between
the management server and a CIM client.
Table 27 Port numbers that must be registered as firewall exceptions between the management server
and a CIM client
RemarksDestinationOriginatorPort number
-Management serverCIM client
427/tcp
This setting is required when
non-SSL communication is used.
Management serverCIM client
5988/tcp
#
This setting is required when SSL
communication is used.
Management serverCIM client
5989/tcp
#
Legend:
-: Not applicable
#:
This port number can be changed.
The following table describes the port numbers that must be registered as firewall exceptions between
the management server and a mail server.
Table 28 Port numbers that must be registered as firewall exceptions between the management server
and a mail server
RemarksDestinationOriginatorPort number
This setting is required to send
an email to a user when the
following events occur:
An alert occurs in a storage
system.
A task executed from the
Migrate Data wizard com-
pletes.
Mail server
#2
Management server
25/tcp
#1
This setting is required to send
an email to a user when the
following events occur:
A task executed from the
Tiered Storage Manager CLI
ends.
A task executed from the
legacy mode Tiered Storage
Manager GUI (the Migration
wizard) ends.
A volume lock period ex-
pires.
The period specified for a
migration group elapses.
Mail server
#3
Management server
25/tcp
#1
#1:
This port number can be changed.
#2:
Network configuration78