HP StorageWorks P9000 Replication Manager Software 7.1 CLI User Guide (TB584-96026, May 2011)

7. Confirm that the file was imported correctly.
Execute the drmexgcat command on backup server B to check whether the backup information
for the date on which backup from the primary volume to the secondary volume was performed
was imported to backup server B.
BKServer B > drmexgcat
STRAGEGROUP: STR1
BACKUP-ID:0000000001 BACKUP-MODE: VSS STRAGEGROUP: STR1 ORIGINAL-ID:0000000001
START-TIME:2007/11/01 10:00:00 END-TIME: 2007/11/01 10:05:00 HOSTNAME:EXG_SRV1
T OBJECT INFORMATIONSTORE FILE FS DG DEVICE
COPY-GROUP
M MAILBOXSTORE MAILBOX1(STR1) D:\STR1\priv1.edb D: - Harddisk1
EXG003,B001
- - - - - - -
EXG003,B001
P PUBLICSTORE PUBLIC1(STR1) D:\STR1\pub1.edb D: - Harddisk1
EXG003,B001
- - - - - - -
EXG003,B001
T TRANSACT - E:\STR1\E00*.log E: - Harddisk2
EXG004,B001
- - - - - - -
EXG004,B001
C CHECKPOINT - E:\STR1\E00.chk E: - Harddisk2
EXG004,B001
- - - - - - -
EXG004,B001
BKServer B >
8. Mount the secondary volume on which the backup data is stored.
Execute the drmmount command on backup server B to mount the secondary volume.
BKServer B > drmmount 0000000001 -mount_pt W:
KAVX0001-I The drmmount command will now start.
KAVX0400-I Mounting will now start.
Mount point = W:
KAVX0401-I Mounting has finished.
Mount point = W:
KAVX0400-I Mounting will now start.
Mount point = X:
KAVX0401-I Mounting has finished.
Mount point = X:
KAVX0002-I The drmmount command will now end.
BKServer B >
Operation for Exchange databases450