HP StorageWorks P9000 Replication Manager Software 7.1 CLI User Guide (TB584-96026, May 2011)

HORCMINST=1
HORCMINST_AUX=2
RETRY_TIME=120
RETRY_WAIT=5
VENDER=HITACHI
PRODUCT=OPEN-3
INSTALLPATH=C:\HORCM
RAID Manager-linkage definition file, for the backup server
(C:\Program Files\CVXPAE\DRM\conf\raid\DEFAULT.dat)
HORCMINST=2
HORCMINST_AUX=1
RETRY_TIME=120
RETRY_WAIT=5
VENDER=HITACHI
PRODUCT=OPEN-3
INSTALLPATH=C:\HORCM
For details about the RAID Manager-linkage definition file (DEFAULT.dat), see Application
AgentSetting up Application Agent for linkage with RAID Manager on page 118.
Example of creating dictionary map files
Since this environment configuration example uses an active-passive cluster configuration, the dictionary
map files are created on the shared directory. In this example, the dictionary map file directory is
L:\PTM.
To create dictionary map files, open an MS-DOS prompt on the database server (active server), and
execute the following command (utility):
PROMPT> set DRM_HOSTNAME=SQL001
PROMPT> C:\Program Files\CVXPAE\DRM\bin\util\drmdbsetup -i
Check that the dictionary map files have been created in the shared directory L:\PTM.
For details about creating dictionary map files, see Creating dictionary map files on page 132.
Example of registering SQL Server information
The following shows an example of registering SQL Server information. Since this environment
configuration uses an active-passive cluster configuration, SQL Server information is created in the
shared directory. In this example, such information is registered in L:\mssql.
To register SQL Server information, execute the drmsqlinit command on both the active server
and the standby server. In this example, since the SQL Server instance uses a set instance, specify
the DEFAULT parameter.
CLI User Guide 527