9. Use the cluster management application to enable failover of the resource group.
Change the settings of the resources listed below.
HP StorageWorks XP Tiered Storage Manager
DeviceManagerServer
HCS Device Manager Web Service
HBase 64 Storage Mgmt Web Service
HBase 64 Storage Mgmt Common Service
HiRDBClusterService _HD1
HP XP7 Command View Advanced Edition product resources other than the above
Right-click the resource names, and then from the Policies tab under Properties, select the following
items:
If resource fails, attempt restart on current node
If restart is unsuccessful, fail over all resources in this Role (or If restart unsuccessful, fail over
all resources in this service or application)
10. In the cluster management application, bring online the resource group in which the HP XP7
Command View Advanced Edition product services are registered.
11. On the executing node and standby node, change the value of the
server.base.initialsynchro property on the Device Manager server back to false.
12. On the executing node and standby node, change the value of the
server.base.initialsynchro property on the Tiered Storage Manager server back to
false.
13. If you specified ALL or DeviceManager for the type option, refresh the storage system from
the Device Manager GUI or CLI.
14. If you restored the management server database at the Replication Manager secondary site,
refresh the configuration information by using the Replication Manager GUI to synchronize the
Replication Manager database at the primary site and the Device Manager database at the
secondary site.
15. Check the status of Device Manager tasks from the Device Manager GUI.
If a Device Manager task is not completed or has failed, re-create the task or change the execution
schedule of the task as necessary.
16. See the message log of Tiered Storage Manager.
When Tiered Storage Manager is started for the first time after a database is restored, make
sure that the message KATS50354-E is output to a log file. The task IDs of Tiered Storage Manager
tasks whose status was changed to Failure are output to KATS50354-E.
17. See the volume information of the tasks indicated in the message KATS50354-E and check
whether those tasks are completed.
Check for completion of not only migration tasks but also shredding tasks and locking tasks.
18. If a Tiered Storage Manager task is not completed, create and execute the task again as necessary.