5. Use the cluster management application to suppress failover of the resource group.
Change the settings of the resources listed below.
HP StorageWorks XP Tiered Storage Manager
DeviceManagerServer
HCS Device Manager Web Service
HBase 64 Storage Mgmt Web Service
HBase 64 Storage Mgmt Common Service
HiRDBClusterService _HD1
HP XP7 Command View Advanced Edition product resources other than the above
Right-click the resource name, and choose Properties, the Policies tab, and then If resource fails,
do not restart.
6. Execute the hcmds64dbrepair command to restore the database.
installation-folder-for-HP-XP7-Command-View-Advanced-Edition\Base64\bin\hcmds64dbrepair
/trans exported-file
trans
Specify the absolute path to the archive file of the database exported via the hcmds64db-
trans command.
7. On the executing node and standby node, specify true for the
server.base.initialsynchro property on the Device Manager server.
8. On the executing node and standby node, specify true for the
server.base.initialsynchro property on the Tiered Storage Manager server.
9. Use the cluster management application to enable failover of the resource group.
Change the settings of the resources listed below.
HP StorageWorks XP Tiered Storage Manager
DeviceManagerServer
HCS Device Manager Web Service
HBase 64 Storage Mgmt Web Service
HBase 64 Storage Mgmt Common Service
HiRDBClusterService _HD1
HP XP7 Command View Advanced Edition product resources other than the above
Right-click the resource names, and then from the Policies tab under Properties, select the following
items:
If resource fails, attempt restart on current node
If restart is unsuccessful, fail over all resources in this Role (or If restart unsuccessful, fail over
all resources in this service or application)
10. In the cluster management application, bring online the resource group in which the HP XP7
Command View Advanced Edition product services are registered.
11. On the executing node and standby node, change the value of the
server.base.initialsynchro property on the Device Manager server back to false.
12. On the executing node and standby node, change the value of the
server.base.initialsynchro property on the Tiered Storage Manager server back to
false.
13. Refresh the storage system from the Device Manager GUI or CLI.
Administrator Guide (Web Version) 183