customizedsnmptrap.customizelist = \
enterprise-ID-1:generic-trap-number-1:specific-trap-number-1:
severity-1:content-to-be-output-1, \
enterprise-ID-2:generic-trap-number-2:specific-trap-number-2:
severity-2:content-to-be-output-2, \
...
enterprise-ID-n:generic-trap-number-n:specific-trap-number-n:
severity-n:content-to-be-output-n
Table 110 Items specified in the customizedsnmptrap.customizelist property
RemarksFormatItem
Required
Specify by using dots (for example,
.1.3.6.1.4.116.3.11.1.2)
enterprise-
ID
RequiredNumeric value, from 0 to 6
generic-
trap-number
RequiredNumeric value
specific-
trap-number
This item is optional. If you omit this item, Null
is assumed.
The severity indicators in the message IDs are
output as follows:
-I for Information
-W for Warning
-E for Error, Critical, and Alert
No log data is output for Null
Specify the severity of each trap by using
one of the character strings below.
You cannot use character strings other
than the following:
Information
Warning
Error
Critical
Alert
Null
severity
Optional. If you omit this item, the $a$e$g$s
content is output.
If you specify Null for the severity, specification
for this item is disabled. Information output for
each variable is as follows:
$a: Agent address (dotted format)
$e: Enterprise ID (dotted format)
$g: Generic trap number
$s: Specific trap number
$n (where n indicates an integer, which is
1 or larger): The value of the nth variable is
binding
Specify the content to be output by using
the character strings (variables) below.
You cannot use character strings other
than the following:
$a
$e
$g
$s
$n (where n indicates an integer,
which is 1 or larger)
content-to-
be-output
You can omit some items, but you cannot omit the colon delimiter.
To specify more than one customization definition, use a comma as a delimiter, but do not enter
a comma at the end of the last entry.
To move to a new line in the customization list, enter a back slash (\) at the end of that line. The
line feed following the back slash (\) is ignored.