HP XP7 Command View Advanced Edition Administrator Guide (Web Version) (TK981-96004, May 2014)

Default: false
Normally, the values set for these parameters do not need to be changed. To change their values,
you need expert knowledge of the Device Manager agent.
agent.rm.shutdownWait
Specify the wait time when stopping the HORCM instance for monitoring (in seconds).
Specify a value from 1 to 60.
Default: 5
agent.rm.horcmInstance
Specify the instance number of the HORCM file for monitoring.
Specify a value from 0 to 4,094. This value must be different from the instance number of other RAID
Manager configuration definition files.
Do not set a value from 990 to 998 because Device Manager agent uses these values by default.
Default: 4094
TIP:
The instance numbers for use by the Device Manager agent can be changed by using the
server.agent.rm.temporaryInstance property in the server.properties file.
Related topics
server.agent.rm.temporaryInstance, page 390
agent.rm.horcmService
Specify the UDP port number of the HORCM file for monitoring.
Specify a value from 0 to 65,535. This value must be different from the port number of other
applications.
Do not set a value from 53,232 to 53,330 because the Device Manager agent uses these values by
default.
Default: 54323
TIP:
The UDP port numbers for use by the Device Manager agent can be changed by using the
server.agent.rm.temporaryPort property in the server.properties file.
Related topics
server.agent.rm.temporaryPort, page 390
Administrator Guide (Web Version) 379