HP XP7 Command View Advanced Edition Administrator Guide (Web Version) (TK981-96004, May 2014)

- If there is one host that recognizes the P-VOL and one host that recognizes the S-VOL, install
a Device Manager agent on each of the hosts.
- If there are multiple hosts that recognize the P-VOL and multiple hosts that recognize the S-
VOL, install a Device Manager agent on one of the hosts that recognize the P-VOL and one
of the hosts that recognize the S-VOL.
Note that if you manage copy pairs defined in a snapshot group, install a Device Manager
agent on the host that recognizes the P-VOL (and you do not need to install it on the host that
recognizes the S-VOL).
RAID Manager must be installed on hosts as follows:
If there are multiple hosts that recognize the P-VOL and multiple hosts that recognize the S-
VOL, install RAID Manager on one of the hosts that recognize the P-VOL and one of the hosts
that recognize the S-VOL.
If the command devices recognized by a host support the authentication function, install version
01-25-03/01 or later of RAID Manager on the host.
If there are multiple NICs on the host, the Device Manager agent and RAID Manager must
use the same IP address.
Copy pair (P-VOL and S-VOL) conditions:
The P-VOL and S-VOL must be managed by a single management server (Device Manager
server).
The P-VOL and S-VOL must be recognized by the hosts (application servers). Note that if you
manage copy pairs defined in a snapshot group, the S-VOL does not need to be recognized
by the hosts.
HP recommends that P-VOL and S-VOL be assigned to separate hosts.
From the P-VOL or S-VOL, LUN security must be set for the host (application server).
From the P-VOL and S-VOL, LUN security can be set for different hosts.
Command device conditions:
Both the host that recognizes the P-VOL and the host that recognizes the S-VOL must recognize
a command device. Note that if you manage copy pairs defined in a snapshot group, the
host that recognizes the S-VOL does not need to recognize a command device.
From a command device, LUN security must be set for the hosts that recognize the P-VOL or
S-VOL.
For a host that recognizes the P-VOL, LUN security must be set from the command device on
the P-VOL side. For a host that recognizes the S-VOL, LUN security must be set from the com-
mand device on the S-VOL side.
System configuration and requirements46