HP XP7 Command View Advanced Edition Administrator Guide (Web Version) (TK981-96004, May 2014)

Storage system requirements for managing copy pairs
Set up the environment in accordance with the storage system requirements.
Table 6 Storage system requirements for managing copy pairs
RequirementsFunctionStorage system
Prerequisite software for Continuous Access
Journal must be installed and the license must
be enabled.
There must be a fibre-channel connection
between the two ports used for an MCU-RCU
path.
#2
The MCU port for an MCU-RCU path must be
an Initiator port, and the RCU port must be an
RCU Target port.
#2
The RCU and the MCU-RCU path must be re-
gistered in the MCU.
#2
The storage system cache or non-volatile memory
must be sufficient.
Journal volumes must be registered in the journal
group.
Note:
After configuring the ports, you need to refresh
the storage system. If you need to increase the
cache, contact maintenance personnel.
Continuous Access Journal
#1
HP XP7
P9500
XP24000
XP20000
XP12000
XP10000
SVS200
Prerequisite software for Continuous Access must
be installed and the license must be enabled.
There must be a fibre-channel connection
between the two ports used for an MCU-RCU
path.
The MCU port for an MCU-RCU path must be
an Initiator port, and the RCU port must be an
RCU Target port.
The RCU and the MCU-RCU path must be re-
gistered in the MCU.
The storage system cache or non-volatile memory
must be sufficient.
Note:
After configuring the ports, you need to refresh
the storage system. If you need to increase the
cache, contact maintenance personnel.
Continuous Access
#1
Prerequisite software for Business Copy must be in-
stalled and the license must be enabled.
Business Copy
#1
System configuration and requirements58