HP P9000 Command View Advanced Edition Suite Software 7.4.1-00 Release Notes (TB581-96338, March 2013)

Reschedule Tasks
If tasks for which the start time passed are selected from the task list in the Tasks & Alerts tab and
Reschedule Tasks is executed, Reschedule Tasks does not complete successfully and generates the
following incorrect message:
KAIC63504-E Unable to execute task. (task name = "<task name>"
Note that the rescheduling tasks for which the start time passed is not supported in Reschedule Tasks.
The server.dispatcher.daemon.autoSynchro.logicalGroup.doRefresh
property
Even if true is specified to the
server.dispatcher.daemon.autoSynchro.logicalGroup.doRefresh property in the
dispatcher.properties file, information on logical groups is not updated automatically when
any CLI commands are executed.
Smart Tiers for Mainframe
If Device Manager is managing XP P9500, Smart Tier for Mainframe pools are displayed as Thin
Provisioning for Mainframe pools.
As a result, all attributes specific to Smart Tier for Mainframe (for example, tier information) cannot
be viewed in Device Manager. Use Element Manager to view the attributes specific to Smart Tier for
Mainframe.
Unallocating volumes and deleting storage for Plug-in for Virtualization Server
Provisioning by selecting hosts in the GUI
In the Unallocate Volumes dialog box or the Delete Storage dialog box, the KAIC15457-E error
message appears, tasks cannot be created, and WWN is removed from a host group when all of the
following conditions are met:
Several WWNs belonging to hosts are assigned to a host group.
The host group in the first condition has 257 or more LUNs.
In the hosts in the first condition, you open the Unallocate Volumes dialog box or the Delete Storage
dialog box by selecting some of the hosts.
If the security of any WWN is removed from a host group, execute the
DeleteWWNForHostStorageDomain CLI command.
Displaying information on Plug-in for Virtualization Server Provisioning and VMware
vSphere Client
Some information on a datastore or a virtualization server displayed on the Plug-in for Virtualization
Server Provisioning might be different from the information displayed on the VMware vSphere Client.
In this case, restart the Pegasus in the vMA, and ask a storage administrator to refresh the information
on the virtualization server that Device Manager manages.
Loading a window of the Plug-in for Virtualization Server Provisioning
A dialog box with the message Are you sure you want to navigate away from this
page? might be displayed while the Plug-in for Virtualization Server Provisioning is used.
If this occurs, click the Cancel button on the dialog box.
Meter-based Term License
When only the Meter-based Term license is registered, an Emergency license cannot be input.
14 Important considerations