HP StorageWorks P9000 Command View Advanced Edition Software 7.1.0-00 Release Notes (TB581-96047, October 2011)

14
Upgrading Command View Advanced Edition to 7.1.0, or importing a
Command View Advanced Edition 7.0.0 database:
When either of the following conditions is met, the KAIC16029-E message might be displayed, and
login fails.
Command View Advanced Edition 7.0.0 is upgraded to Command View Advanced Edition 7.1.0.
Command View Advanced Edition 7.1.0 is installed, and then a Command View Advanced
Edition 7.0.0 database is imported.
In this case, restart the Device Manager service.
When Replication Manager is used and copy group information is
viewed
From the Pair Configurations view in Replication Manager, the value displayed for the number of
viewable copy pairs in the Visible/Total column in the Copy Group Summary is sometimes different
from the actual number of copy pairs displayed in the Pairs tab.
The total number of copy pairs displayed in the Pairs tab is the actual number of viewable copy
pairs.
This issue occurs when all of the following conditions are met:
The Replication Manager license is not registered, and Replication Manager is started from
Device Manager.
From the Pair Configurations view (accessible via the Explorer menu, Resources, and then Pair
Configurations, the Copy Pair Summary is viewed, which is accessible by selecting Pair
Configurations, Pair Management Servers, Config Files, and then Copy Groups.
Copy pairs that cannot be viewed are in the copy group selected in the previous issue.
The shrink pool
An KAIC60003-E error might appear without the message when using shrink pool.
In this case, confirm if the shrink pool task has completed in Element Manager. If the shrink pool
task has completed in Element Manager, execute the format task.
Refresh the storage system by using P9000 Command View AE Software after the format task
completes.
Creating a pool
The error Assertion Failed:AsynchronousProcessCounter#decrement(KAIC16993-E)
might appear when one of the following operations is continuously performed in the Create Pool
dialog box.
Addition of tiers
Deletion of tiers
Addition of parity groups
Deletion of parity groups
In this case, close the Create Pool dialog box, and then retry the operation.
The Search window
An KAIC16009-E error might occur when the Search button is clicked right after displaying the
Search window. In this case, close the error dialog box, and then retry the search.